Page 5 - Regent - Electrical Product Guide
P. 5

                                      CABLE & CABLE ACCESSORIES
                        Cable General Wiring
6181Y
• Often known as “Meter Tails” mainly used to connect the Installation to the Electricity providers meter.
• BS6004.
• Voltage rating 300/500V.
6243Y 6491B
                          Part No.
 1.0, 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0 & 35.0
6242Y
• Mainly found in domestic installations as predominantly used for the wiring of houses or where surface mounted cable is required. Offers little protection from damage if not protected.
• BS6004.
• Voltage rating 300/500V.
1.0, 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0
1.0 & 1.5
• Similar to 6242Y but used for Two Way Switching where the extra conductor is required.
• Grey sheath.
• BS6004.
• Voltage rating 300/500V.
1.0 & 1.5
• See 6491X cables
for application but 6491B offers better performance with regards to giving off lower levels of smoke and corrosive gases where a fire may occur.
• BS7211.
         6242Y
6241Y
• Not commonly used but can be suitable when an additional double sheathed conductor is required in addition to 6243Y.
• BS6004.
• Voltage rating 300/500V.
Part No.
Available Sizes mm
 6181Y
 Available Sizes mm
Available Sizes mm
Part No.
Available Sizes mm
6242B 6491X
•
•
See 6242Y for applications but 6242B offers better performance with regards to giving off lower levels of smoke and corrosive gases where a fire may occur.
• Single Insulated Cables that are normally installed in either plastic or metal conduit or trunking to offer protection for multiple circuits.
• BS6004.
Part No.
 6243Y
6491B
   BS7211.
Part No.
Available Sizes mm
 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0 & 95.0
   Part No.
  Part No.
Available Sizes
mm
Available Sizes mm
     6241Y
6242B
1.0, 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0
         Tri-Rated Cables
Single Core Stranded Copper Tri-Rated Cable
• Available in many colours and used very widely by panel builders where the 105degree PVC insulation gives more protection to ambient heat and the numerous colour choices aid identification.
   Part No.
 TRI0.75
Available Sizes mm
   TRI1.5
0.75
 TRI1.0
1.0
  1.5
6942B
1.5, 2.5, 4.0, 6.0, 2 10.0 & 16.0
6491X
1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0 & 95.0
      SWA Cables
694_X & 694_B
Steel Wire Armoured Cable
• SWA, stands for Steel Wired Armour as this
is the method used to protect the cable from accidental damage, Commonly used when buried in the ground
or for surface mounted where more protection is required above 6242Y for example.
Part No. Standard
6942X
Part No. Low Smoke
Available Sizes mm
Cores
Fire Resistant Cables
Multicore Fire Resistant Cables
• A high specification range
of cables used to offer protection from fire. Fire Alarm cables are used for
the wiring of actual fire alarm systems as well in some cases Emergency Lighting. The cable undergoes rigorous tests to ensure it does not deteriorate and fail within strict time and condition tests to enable occupants to evacuate the building.
  TRI2.5
2.5
  TRI4.5
   6943X
6943B
  TRI6.0
  TRI50
4.5
6944X
6944B
6945B
1.5, 2.5, 4.0, 6.0, 3 10.0 & 16.0
Size mm
1.5
2.5
Cores
2+E
2+E
Available Sheath
Red, White & Black
Red, White & Black
Colour
  6.0
   1.5
3+E
  TRI25
25.0
Red, White & Black
 1.5, 2.5, 4.0, 6.0, 4 10.0 & 16.0
   2.5
3+E
  TRI35
35.0
Red, White & Black
   1.5
4+E
     6945X
1.5, 2.5, 4.0, 6.0, 5 10.0 & 16.0
Red, White & Black
   2.5
4+E
 TRI70
50.0
 70.0
Red, White & Black
                Together we generate value
5
   
   3   4   5   6   7