Page 226 - Regent - Electrical Product Guide
P. 226

   FIRE & SECURITY
Fire Alarm Systems
     TWINFLEX®pro2 Bi-Wire System
The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol.
The TwinflexPro2 panel is available in 2,4 & 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector, heat detector and a manual call point alarm.
• Available in 2, 4, and 8 zone panel versions.
• Ability identify between smoke detector,
heat detector and a manual call point alarm.
• Event log storing up to 500 events.
• Up to 32 devices per zone.
• Allows detectors and sounders to be installed on the same pair of wires.
• Day/night mode.
• Alarm confirmation and delay programming
options.
• With the addition of a conventional zone card, a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.
• Incorporates Integral power supply unit.
2 Zone TWINFLEXpro2 Control Panel 4 Zone TWINFLEXpro2 Control Panel 8 Zone TWINFLEXpro2 Control Panel 3.4AH Batteries (x 2 required)
ASD Multi-Point Detector
ASD Multi-Point Detector & Sounder
ASD Multi-Point Detector, Sounder & Beacon
Red Hatari Sounder Flashpoint Sounder + LED Beacon (VID)
Call Point - Resettable Call Point Cover
      Part No.
Sounders / Beacons
Description
    FC-3017
 FC-3019
  Call Points
  FC-3034
 FC-3026
 Part No.
  Panels
Description
  FC-3035
 FC-3036
  FC-3037
  BAT-3002
   Detectors
   FC-3046
  FC-3047
  FC-3048
     Addressable Alarm Systems
• 1, 2, 4 or 8 Loop formats.
• Up to 254 devices per loop
(Protocol dependent).
• Up to 1000 fire detection zones.
• Up to 188,800 devices per network.
• True peer-to-peer networking.
• Networkable up to 200 nodes.
• Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers.
• Circuit monitoring of local panel circuits.
• Autolearn and Loop detection.
• Simple Select & Click programming.
• 1000 event log entries.
• Simplified logic delivers click and go configuration.
• Built in voltage and current meters.
• Quick start and protect - a working system
after an Autolearn is performed.
• Single area false alarm management.
• Optional Peripheral expansion card.
• Programmable logo on screen.
• Compatible with Apollo Discovery and XP95, Argus Vega, Hochiki ESP and Nittan Evolution protocols.
• Approved to EN54 parts 2 and 4.
1 Loop Addressable Panel
2 Loop Addressable Panel
8 Loop Addressable Panel Intelligent Input / Output Unit
Optical Smoke Detector Heat Detector Detector Base
Sounder Base & Isolator Sounder / Beacon Base & Isolator (VID) Sounder / Beacon Base & Isolator (VAD) Wall Sounder & Isolator
Wall Sounder / Beacon + Isolator (VID) Wall Beacon + Isolator (VID)
Call Point & Isolator Call Point Protective Cover
     Part No.
  Panels
Detectors
Description
Part No.
Sounders / Beacons
  AP-1000
 AP-1014
AD-2018
Description
    AD-2016
     AP-1019
AD-2072
    ADI-2025
AD-2037
    AD-2038
    AD-2000
AD-2031
    AD-2002
Call Points
    AD-2005
AD-2068
    AD-2070
     226
Together we generate value
      