  Circuit Protection
   Defender Consumer Boards
 Populated High Integrity Split Load Dual RCD Consumer Units
• A comprehensive range of single phase consumer Type tested to BS EN 61439-3 and 18th Edition Wiring Regulations.
• A modern sleek design suitable for all installations.
• Comprehensive range comprising 10 different enclosures sizes.
• Up to 22 module board as standard; combine • boards to increase number of outgoing ways. •
• Maximum cable space and extensive • number of cable entry points allowing easy installation. •
• Comprehensive user instructions and high •
Optional surge protection available. Flexible board configuration to enable
optimal combination of RCD, MCB and RCBO use.
Pre-populated configurations available.
Part No.
DDS06166MS-P01
DDS06188MS-P01
DDS08188MS-P01
quality sub circuit identification labels. • Degree of protection IP4X.
Secure hinge design. • Locking kits available.
 Description
  6 Way 100A Switch + 2 x 63A RCD c/w 1 x 40A, 2 x 32A, 1 x 16A, 2 x 6A MCB’s
6 Way 100A Switch + 2 x 80A RCD c/w 1 x 40A, 2 x 32A, 1 x 16A, 2 x 6A MCB’s
8 Way 100A Switch + 2 x 63A RCD c/w 1 x 40A, 3 x 32A, 1 x 16A, 2 x 6A MCB’s
8 Way 100A Switch + 2 x 80A RCD c/w 1 x 40A, 3 x 32A, 1x 16A, 2 x 6A MCB’s
10 Way 100A Switch + 2 x 63A RCD c/w 1 x 40A, 4 x 32A, 2 x 16A, 3 x 6A MCB’s 10Way100ASwitch+2x63ARCDc/w1x40A,4x32A,2x16A,2x6AMCB’s+1x6ARCBO 10 Way 100A Switch + 2 x 80A RCD c/w 1 x 40A, 4 x 32A, 2 x 16A, 3 x 6A MCB’s
10 Way 100A Switch + 2 x 80A RCD c/w 1 x 40A, 4 x 32A, 2 x 16A, 2 x 6A MCB’s
+ 1 x 6A RCBO
12 Way 100A Switch + 2 x 80A RCD c/w 1 x 40A, 4 x 32A, 2 x 16A, 3 x 6A MCB’s
14 Way 100A Switch + 2 x 80A RCD c/w 1 x 40A, 4 x 32A, 2 x 16A, 3 x 6A MCB’s + 1 x 6A RCBO & 3 Blank Ways
16 Way 100A Switch + 2 x 80A RCD c/w 1 x 40A, 4 x 32A, 2 x 16A, 3 x 6A MCB’s
10 Way 100A Switch + 1 x 40A, 2 x 32A, 1 x 16A + 2 x 6A RCBO’s & 4 Blank Ways
10 Way Populated 100A Switch + 8 RCBO’s
Garage Unit 2 Way 63A RCD + 1 x16A, 1 x 6A MCB’s
DD101MS-PO2
    DDS08166MS-P01
    DDS10166MS-P01
  DDS10166MS-P02
  DDS10188MS-P01
 DDS10188MS-P02
  DDS12188MS-P01
  DDS14188MS-P01
  DDS16188MS-P01
  DD101MS-P01
  DD101MS-PO2
  DR026MS-P01
     Shower & Time Delay Enclosures
Part No.
 DTDDR001MS
DSPE1MS
Description
100A Time Delay RCD Incomer TT/CU
40A RCD Shower Enclosure - No O/G Ways
63A RCD Shower Enclosure - 1 O/G 50A MCB
114 x 260 x 130
114 x 260 x 130 150 x 260 x 130
Size W x H x D (mm)